repeat">
Chemtron Science Laboratories Private Limited
Chemtron Science Laboratories Private Limited
mahape, Thane, Maharashtra
GST No. 27AACCC3596J1ZC
08048955732 85% Response Rate
Send E-mail

Calibration Gas

Providing you the best range of calibration gases for cdqc, calibration gas mixtures for oil & gas, calibration gas mixture for cems & aqms, calibration gas mixture for automotive test, calibration gas standard for dissolved gas analysis/ toga and process gas mixtures with effective & timely delivery.
Request CallBack
Calibration gases for CDQC
Get Best Quote

Calibration gases for CDQC

Approx. Price: Rs 35,000 / PieceGet Latest Price
Product Details:
Capacity10L to 50L
Usage/ApplicationCalibration of CDQC Analyzers and Gas Chromatography
BrandChemtron_CSL
Available GasesAll Types
Body MaterialAluminum
Concentration Rangeppb to 1000 ppm
Cylinder MaterialAluminum
Cylinder Volume10L to 50L
FeatureAccurate to 2 to %
FlammableNo
FormGas
PortableAvaillable
Pressure130 to 150 kg/cm2
Toxicityyes
Country of OriginMade in India
Calibration gas standards for Carbon Dioxide Quality Check (CDQC) Analyzsrs & GCs

Carbon Dioxide is usually used in food & beverages industry to preserve the quality of food products and carbonization of beverages.
Because of high demand of improved quality and purity of Carbon Dioxide (CO2), manufacturer must compulsorily install the impurity check analyzers or quality check analyzers. It is very challenging for analyzer service providers to calibrate these analyzers for given impurity components.
Here, we at CSL are constantly developing certified calibration gas standards prepared gravimetrically (ISO 6142) and analyzed on very accurate Gas Chromatography.
Our Calibration gas Standards are widely used by CO2 manufacturer, system integrators & calibration service providers.
We offer all Types of calibration gases for CDQC analyzer systems.

Calibration Gas Mix / Standards for Total Sulfur Analyzer

 

ComponentsConcentration (v/v) or (mol/mol)
Cal Gas 1Cal gas 2Cal Gas 3Cal Gas 4Cal Gas 5Cal gas 6
Hydrogen Sulfide 100 to 200 PPB 100 to 200 PPB 1 ppm 1 to 20 ppm - -
Methyl Mercaptan - - 1 ppm - 1 to 20 ppm -
Methyl Ethyl Sulfide - - 1 ppm - - -
Carbonyl Sulfide - - 1 ppm - - 1 to 20 ppm
Carbon Disulfide - - - - - -
Sulfur Dioxide - - - - - -
Dimethyl Sulfide - - - - - -
Nitrogen BALANCE % - Balance % Balance % Balance % Balance %
Carbon Dioxide - BALANCE % - - - -

Calibration Gas Standards for Total Hydrocarbon in CO2Calibration Gas Standards for Trace Aromatics & OxygenatesCalibration Gas Standards for Trace Oxygen
  • We can supply as low as 2 ppm O2 in CO2 or N2
  • Standard Calibration Gas for CDQC is 20 to 40 ppm Oxygen in Carbon Dioxide
  • The CO2 used will be free of HCs and Sulfides
Gas Standard for Zero Calibration of Total HCs/ Sulfides
  • Mainly High Pure Carbon dioxide is used for Zero Calibration
  • We supply High Purity Carbon Dioxide with traces of known impurities
  • Purity of Carbon dioxide (CO2) is 99.999%
High Pure Hydrogen (with <1 ppm THC) as Fuel Gas.


Additional Information:
  • Item Code: CSL_CDQC_CYL
  • Production Capacity: 30000
  • Delivery Time: 8 weeks
  • Packaging Details: 10L to 50L
Yes! I am interested
Request CallBack
Calibration Gas Mixtures for OiL & Gas
Get Best Quote

Calibration Gas Mixtures for OiL & Gas

Approx. Price: Rs 20,550 / PieceGet Latest Price
Product Details:
Gas Mixture TypeEmission Standard, Gas Mixture, Nuclear Mixture
Packaging Size10L
BrandChemtron-CSL
Purity>=99.99%
Usage/ApplicationREFINERY & PETROCHEMICALS
Grade StandardTraceable to NIST/NPL
ShapeCylindrical
Water Capacity0.5L /1.6L/3L/5L/10L/20L/35L/47L/50L
Pressure Rangemaximum 200 kg/cm2
Model Name/NumberCSL_CALGAS_CYL
Country of OriginMade in India
Calibration Gas Standards for Petrochemicals and Refinery

CSL offers certified gas standards which provides the ultimate in accuracy and traceability for the most demanding analytical applications, such as process analyzers in refineries and petrochemicals.
  • Excellent lead times
  • Prepared by high precision gravimetry
  • Verified analytically by traceable comparison methods
  • Fully compliant with ISO 6142 – Part 1 and ISO 6143
Refinery Lab Calibration Gas Standards

The following shows some of the common calibration gas standards available from CSL.

Please inquire for product availability if your calibration gas or specialty gas requirements are not shown below.

Sulfur Species - CALIBRATION GAS STANDARDS

  • Fuel Gas Plants (method 11 Hydrogen Sulfide mixtures)
  • Miscellaneous (PPB & PPM Hydrogen Sulfide, Carbonyl Sulfide, Sulfur Dioxide, Methyl Mercaptan, Ethyl Mercaptan, Thiophene, Carbon Disulfide & Dimethyl Disulfide)

Natural Gas Standards
Natural gas composition varies from source to source and often varies on a daily and seasonal basis. Using a calibration gas that is specifically designed for your application ensures that you will continue to achieve the best possible gas quality measurements. CSL’s experienced staff posses over twenty years of experience in gas industry to design calibration gases to suit each customer’s specific requirements.Mix of C10 to C12, CO2, N2 and other Permanent or Aromatic gas components.
Other Applications of Natural Gas Standards
  • Sulfides & Mercaptans in Natural Gas Composition
  • Liquified Natural Gas (LNG) Standards in Constant Pressure Piston Type Cylinder, as shown below

Calibration Gas Standards for Refinery Gas Analyzers (RGA) 
Various Composition of refinery gas analyzer standards are as follows. Any other feasible combination can be supplied on request.
LPG GAS STANDARDS

Various combination of LPG gas standards are used to Calibrate the Gas Chromatography in refinery labs.
Methanizer Calibration Gas Standards
Calibration gas mix of ppm of CO, CO2 & Methane balance Hydrogen E.g. 5 ppm each of CO, CO2 & Methane in Hydrogen with Accuracy of ±3 % and stability of 24 months.

Petrochemicals/ Polymer Plant Calibration Gas StandardsCALIBRATION GAS & LIQUID STANDARDS FOR BUTENE/BUTADIENE/AROMATICS
  • Gas or liquid blends of C1/C2/C3C4/C5+ components like Methane, Ethane, Propane, Propylene, Ethane , Ethylene, Butanes, Pentanes, Acetylenes (Vinyl, Methyl, Ethyl, Propyl etc), 2-Butenes (Cis & trans), Pentenes
  • Liquid blends of BTEX, other aromatics & higher Alkanes (mol/mol , vol/vol & wt/wt)
  • Calibration gas and liquid blends for impurity profile in 1,3–Butadiene
  • Calibration gas and liquid blends for impurity profile in 1-Butene
  • Liquid blends for LPG (C1 to C6+)
  • Other customized liquid blends for Hydrocarbons
  • Other customized liquid blends for Sulphur in hydrocarbons available in Helium overpressure cylinder or constant pressure piston type sampling cylinders
    • Sulphur as Thiophene or Mercaptans in iso-Octane
    • Sulphur in Butanes
    • Sulphur in Propane
    • Sulphur in Ethylene/Propylene
  • Liquified LPG gas standard in constant pressure piston type sampling cylinders

Calibration Gas Blends / Standards For Oil & Gas ExplorationAnalyzer or GC shelters installed at Oil & Gas platforms requires continuous calibration to check the accuracy of the analysis in critical processes.

Mud Logging Analyzer / GC Gas StandardsCalibration Gas Standards for Natural Gas

Additional Information:
  • Production Capacity: 40000
  • Delivery Time: 4 TO 10 WEEKS
  • Packaging Details: CYLINDERS
Yes! I am interested
Request CallBack
Calibration Gas Mixture for CEMS & AQMS
Get Best Quote

Calibration Gas Mixture for CEMS & AQMS

Approx. Price: Rs 20,000 / PieceGet Latest Price
Product Details:
Gas Mixture TypeEmission Standard, Gas Mixture
Packaging Size3L to 20L
BrandChemtron-CSL
Purity>=99.99%
Usage/ApplicationTo Calibrate dissolved gas analyzer or gas chromatography
Grade StandardTraceable to NIST/NPL
ShapeCylindrical
Water Capacity0.5L /1.6L/3L/5L/10L/20L/35L/47L/50L
Pressure Rangemaximum 200 kg/cm2
Model Name/NumberCSL_CALGAS_CYL
Country of OriginMade in India
Calibration Gas Standards For Environment Monitoring SystemCalibration Gas For CEMS
Traceable Calibration Gas Standard for Stack and CEMS
ComponentsRangeShelf Life in MonthsAccuracy
Nitric Oxide + Sulfur Dioxide in Nitrogen  500 ppm each 12/24 ±1%
Sulfur Dioxide in Nitrogen 5-2000 ppm 12/24 ±1%
Nitric Oxide in Nitrogen 5-2000 ppm 12/24 ±1%
Carbon Monoxide in Nitrogen 5-1600 ppm 12/24 ±1%
Sulfur Dioxide + Nitric Oxide + Carbon Monoxide + Carbon Dioxide in Nitrogen 0.02%- 0.5% each 12/24 +/1%

Any other feasible gas blends/standards can be supplied as per required composition.

Traceable Calibration Gas Standard For Stack and CEMS

 

ComponentsRangeShelf Life in MonthsAccuracy
Carbon Dioxide in Nitrogen 0.001% - 0.5% 12 ±1%
Oxygen in Nitrogen 0.4%/8% 12 ±1%
Carbon Monoxide + Carbon Dioxide in Nitrogen 5 PPM -5% each 12 ±1%
Carbon Monoxide +Oxygenin Nitrogen 0.005%-3%each 12 ±1%

Any other feasible gas blends/standards can be supplied as per required composition.

TRACEABLE CALIBRATION GAS STANDARD FOR AQMS

 

ComponentsRangeShelf Life in MonthsAccuracy
Nitric Oxide in Nitrogen / Air  5-50 ppm each 12  ±1%
Sulfur Dioxide in Nitrogen / Air 5-50 ppm each 12  ±1%
Carbon Monoxide in Nitrogen / Air 5-500 ppm 12 ±1%

Any other feasible gas blends/standards can be supplied as per required composition.

Traceable Calibration Gas Standard for AQMS
ComponentsRangeShelf Life in MonthsAccuracy
Ammonia in Nitrogen / Air 5-50 ppm 12 ±1%
Methane / Carbon Monoxide in Nitrogen / Air 5-50 ppm 12 ±1%
Hydrogen Chloride in Nitrogen  5-25 ppm 3/6  ±1%
Chlorine in Nitrogen 5-25 ppm 3/6  ±1%
Benzene + Toluene + Ethyl Benzene + Xylene on Nitrogen 100 ppb-5 ppm 12  ±1%

Any other feasible gas blends/standards can be supplied as per required composition.



Additional Information:
  • Item Code: CSL_CEMS_CYL
  • Production Capacity: 40000
  • Delivery Time: 3 to 5 weeks
  • Packaging Details: Cylinder
Yes! I am interested
Save time! Get the Best Deal

*Your information is safe with us.

Request CallBack
Calibration Gas mixture for Automotive Test
Get Best Quote

Calibration Gas mixture for Automotive Test

Approx. Price: Rs 25,000 / PieceGet Latest Price
Product Details:
Gas Mixture TypeGas Mixture, Emission Standard
Packaging Size3L to 50L
BrandChemtron-CSL
Purity>=99.99%
Usage/ApplicationTo Calibrate Emission testing Analysers
Grade StandardTraceable to NIST/NPL
ShapeCylindrical
Water Capacity10L/20L/35L/47L/50L
Pressure Rangemaximum 200 kg/cm2
Model Name/NumberCSL_CALGAS_CYL
Country of OriginMade in India
Calibration Gas Standard For Automotive Exhaust Gas AnalyserBenefits and Features:
  • Guaranteed analytical accuracy facilitates precise instrument calibration which ensures ARAI compliance
  • NIST traceability ensures ±1% for most mixture
Analytical Accuracy:

Their purity, accuracy and reliability improve analysis reliability for added compliance assurance. These testing calibration gases specially made for tailpipe analysis and bench testing for all mobile engine application including automotive, off road, locomotive, motor cycle, marine and many other gasoline and diesel applications.

Calibration gas standards for vehicle emission testing analyser:
ComponentsRangeShelf Life in MonthsAccuracyTraceability
Hydrogen in Helium 40% 12/24 ±1% NPL
Carbon Monixide in Nitrogen 10 ppm TO 5000 ppm 12/24 ±1% NIST
Carbon Dioxide in Nitrogen 1% TO 14% 12/24 ±1% NPL
Nitric Oxide in Nitrogen 50 ppm TO 2500 ppm 12/24 ±1% NIST
Propane in Air 4 ppm TO 1500 ppm 12/24 ±1% NIST
Ammonia in Nitrogen 5 ppm TO 5000 ppm 12/24 ±1% NPL
Nitrous Oxide in Nitrogen 50 ppm TO 1500 ppm 12/24 ±1% NPL
Ethane in Air / Nitrogen 0.5 ppm TO 1% 12/24 ±1% NPL
Oxygen in Nitrogen 0.4% TO 25% 12/24 ±1% NPL
Hydrogen in Nitrogen 1% TO 41% 12/24 ±1% NPL
Methane in Air / Nitrogen 0.5 ppm TO 1% 12/24 ±1% NPL
Propane + Carbon Monoxide + Carbon Dioxide in Nitrogen 2000 ppm + 3.5% +14% 12/24 ±1% NPL
Propane + Oxygen + Carbon Monoxide + Carbon dioxide in Nitrogen 2000 ppm + 0.5% + 5% + 14% 12/24 ±1% NPL


Bump Testing Calibration Gases:
ComponentsRangeShelf Life in MonthsAccuracyTraceability
Acetaldehyde in Nitrogen 1-1000 ppm 12/24 ±2% NPL
Ethanol in Nitrogen 1-500 ppm 12/24 ±2% NPL
Formaldehyde in Nitrogen 0.5-30 ppm 12/24 ±2% NPL
Methanol in Nitrogen 1-1000 ppm 12/24 ±2% NPL
Propanol in Nitrogen 1-500 ppm 12/24 ±2% NPL


High Pure Gases for Zero Calibration:
GASPURITYIMPURITIES
THC CO CO2 O2 NOx N2O
NITROGEN 99.9999% ≤0.05µmol/mol ≤ 1 µmol/mol ≤10µmol/mol ≤ 2 µmol/mol ≤0.02µmol/mol ≤0.02 µmol/mol
SYNTHETIC AIR 99.9999% ≤0.05µmol/mol ≤ 1 µmol/mol ≤10µmol/mol 20.5% - 21.5% vol ≤0.02µmol/mol ≤0.02 µmol/mol


Additional Information:
  • Item Code: CSL_AUTO_CALGAS
  • Production Capacity: 40000
  • Delivery Time: 4 weeks
  • Packaging Details: Cylinder
Yes! I am interested
Request CallBack
Calibration Gas Standard For Dissolved Gas Analysis/ Toga
Get Best Quote

Calibration Gas Standard For Dissolved Gas Analysis/ Toga

Approx. Price: Rs 30,000 / PieceGet Latest Price
Product Details:
Gas Mixture TypeEmission Standard, Gas Mixture
Packaging Size3L to 20L
BrandChemtron-CSL
Purity>=99.99%
Usage/ApplicationTo Calibrate dissolved gas analyzer or gas chromatography
Grade StandardTraceable to NIST/NPL
ShapeCylindrical
Water Capacity0.5L /1.6L/3L/5L/10L/20L/35L/47L/50L
Pressure Rangemaximum 200 kg/cm2
Model Name/NumberCSL_CALGAS_CYL
Country of OriginMade in India
We are offering wide range of Calibration Gas Standard For Dissolved Gas Analysis/ Toga.

Additional Information:
  • Item Code: CSL_DGA_CYL
  • Production Capacity: 3000
  • Delivery Time: 4 to 6 weeks
  • Packaging Details: Cylinder
Yes! I am interested
Request CallBack
Process Gas Mixtures
Ask For Price

Process Gas Mixtures

Product Price : Get Latest Price
Product Details:
MaterialGAS
Available GasesAs per specs
BrandChemtron_CSL
Capacity10L to 50L
Country of OriginMade in India
Usage/ApplicationLaboratory
Packaging Size10L to 50L
ColorAs per Gas
Binary Gas Process Mixtures

With state-of-the-Art Blending and Analysis facility, CSL can supply various type of standard and customized Binary Mix of gases

  • P10 Gas: Mix of 10% Methane in Argon Balance (90%) - Vol/Vol
  • P5 Gas: Mix of 5% Methane in Argon Balance (95%) - vol/vol
  • 10% Ethane Balance Argon (90%) Vol/Vol

We offer a range of Welding Gas Mixtures for specific applications:
Gas MixturesType of WeldMetal
Argon + NitrogenAuto BulbsCopper & Alloys
Argon + OxygenMIGStainless Steel
Argon + Carbon DioxideMIG Welding Mild Steelcarbon Steel
Argon + HydrogenTIG Welding Stainless SteelStainless Steel



Process & Research Gas Mixtures

Various Experiments requires the predefined mix of gases as their raw material or as fuel for the reaction in process. Depends on the application, we can supply the customized mix of gases as per their concentrations

  • Ammonia (NH3) 100 ppm to 50% v/v Balance Nitrogen (N2) %v/v
  • Ammonia (NH3) 100 ppm to 50% v/v Balance Helium (N2) %v/v
  • Carbon Monoxide 1% to 90% v/v/ Balance Nitrogen (N2) %v/v
  • Chlorine 500 ppm v/v to 5% v/v Balance Nitrogen (N2) %v/v
  • Hydrogen Sulfide (5 to 70 % v/v), Carbon Dioxide Balance % v/v
  • Hydrogen Sulfide (10 to 20% v/v), Carbon Dioxide (10 to 50% v/v), Balance Methane % v/v
  • Sulfur Dioxide (0. 5 to 20 % v/v) in Balance Nitrogen % V/V
  • Oxygen 1.50 % v/v, Deuterium 3.00 % v/v, Nitrogen 3.00 % v/v and balance helium % v/v
  • Oxygen 1.00 % v/v, Deuterium 2.00 % v/v, Nitrogen 2.00 % v/v and balance helium % v/v
  • Oxygen 0.50 % v/v, Deuterium 1.00 % v/v, Nitrogen 1.00 % v/v and balance helium % v/v
  • Nitrogen or Carbon dioxide or Hydrogen 99.50 % v/v and balance helium % V/v



Laser Gas Mixture
  • 3% Xenon (Xe), Helium (He) Balance
  • Helium Now Laser – Composition - 8.3 - 20% Neon, Balance Helium
  • Different blend and analytical specifications apply based on concentration
  • Lasers used in surgical procedures and research
    • 4.5% Carbon Dioxide (CO2) /13.5% Nitrogen (N2) balance Helium (He)
    • 6% Carbon Dioxide (CO2) /14% Nitrogen (N2) /balance Helium (He)
    • 7% Carbon Dioxide (CO2) /14% Nitrogen (N2) / balance Helium (He)
    • 9% Carbon Dioxide (CO2) /15% Nitrogen (N2) /balance Helium (He)
    • 9.4% Carbon Dioxide (CO2) /19.25% Nitrogen (N2) /balance Helium (He)
  • Excimer laser Gas Mixtures
    • 0.1 - 10% Hydrogen Chloride, 1.0 - 10% Xenon, Balance Argon
    • 0.1 - 10% Hydrogen Chloride, 1.0 - 10% Xenon, 30 - 35% Helium, Balance Neon
    • 0.1 - 10% Hydrogen Chloride, Balance Helium

Additional Information:
  • Production Capacity: 20000
  • Packaging Details: Cylinder
Yes! I am interested
X